Search : 
New collections

16-Zone GSM Auto-dial Aalarm system for Home/Business

Price : $53.59

  • Model: iaxiabjT
  • 10000 Units in Stock

Add to Cart:


The GSM Auto-dial Aalarm system for Home/Business is a new security protection solution special for home, house and office and other applications. It based on Wireless GSM Communication network, intergrated Computer technology. When any sensor activated, it will Call&Send SMS to owners telephone immediately.

General Information:

  • Is 16-zone alarm system,very suituable for small office and home appliance.
  • Alarm system uses a GSM communicator, so is no distance limits to receive alarms or dial out to control the alarm system.
  • System can support 850/900/1800/1900 Mhz GSM cell phones.
  • Can store and dial 5 phone numbers (no longer than 15 character each one).If an alarm occurs.numbers will be dialed in order starting with last stored. you can set to dial monitoring center,police and owners.
  • Using remote controllers you can arm,disarm,panic from long distance.
  • You can control the system by using a telephone anytime,wherever you are.For security reasons a PIN code must be used for access.
  • Supports any wired sensors available( NC contacts)
  • Supports any combination of wired / wireless sensors, as you need.
  • No need for fixed telephone line . is very suitable for cottage, house, shop, garage,everywhere a GSM Network is present.
  • For weak GSM signal area an external antenna can be used.
  • There open collector outputs available to be sued according to customer demands.
  • One onboard replay available for customer application.
  • Easy to be installed and operated according to the instruction from the manual. 

Technical Parameters:

    GSM Alarm module:
  • Operating voltage: DV 6V
  • Average power: AC/DC exchanger 2A.
  • Wireless receiving distance: 100M
  • Operating Frequency :315 or  433.92 MHZ
  • GSM Frequency: 900-1800MHZ , 850-1900MHZ is optional.
  • Operating voltage: DC 12V, AC 220/110V
  • Wierless receiving distance : 100m-250m.

    Outer Alarm siren:
  • Volume: 10dB
  • Working condition: Temperature  -10°C + 40°C
  • Humidity : 90% rh

    Wireless Gap Detector  (Door / Window Contact)
  • Power Supply: DC 12V ( Inner 12V bettery )
  • Satic Current : ≤20mA
  • Transmission Current: ≤15 mA
  • Transmission Ferquency :315/433 MHZ±0.5MHZ
  • Transmission Distance: No obstacle 100m
  • Internal distance: 15mm
  • Working condition: Temperature  -10°C + 40°C
  • Humidity : 90% rh

    Wireless P.IR Detector
  • Power Supply: DC 9V (Inner 9V bettery )
  • Satic Current : ≤100mA
  • Transmission Current: ≤20 mA
  • Transmission Ferquency :315/433 MHZ±0.5MHZ
  • Transmission Distance: No obstacle 100m
  • Detective Speed : 0.3-3m/s
  • Detective distance :5- 12m
  • Detective Range: Horizontal 110°  Vertical 60°
  • Working condition: Temperature  -10°C + 40°C
  • Humidity : 90% rh

    Remote Control:
  • Power Supply: DC 12V ( Inner 12V bettery )
  • Transmission Current: ≤15 mA
  • Transmission Ferquency :315/433 MHZ±0.5MHZ
  • Transmission Distance: No obstacle 100m

Basic Kit Contains:

  • Aalrm system (control unit) x1
  • wireless PIR detector x1
  • wireless door (gap) sensor x1
  • Remote controller x2
  • Antenna x1
  • Mini wired siren  110dB /0.3m x1
  • Power supply with back-up x1
  • Installation/user manual x1

FAQ - Frequently Asked Questions

  • Resetting the system.
    NOTICE! Resetting the system all coded information and messages will be lost. System will be loaded with basic factory settings. The passwords will be back to the original default- 123456. you must code/ register all wireless sensors again after reset.
    Reset procedure:
    - System must be disarmed.
    -  Press reset button and keep it pressed
    -  Plug off 12V Supply from alarm system
    -  Plug on 12V supply at alarm system again, alarm LED will have a brief flash
    -  Release rest button and let system LED to boecome green.
    Now system is reset and back to factory settings. (the passwords is  123456)

  • How to add the new sensors with the alarm system (Registering wireless sensors with control unit )
    If you use only kit sensors, system is ready to be power on. sensors and remote controls delivered in kit are already coded (registered) in the system by factory. Plug  in DC 12V power supply  in alarm system. 
    if the alarm system needs to add the new sensors, such as wireless door gap sensors,remote controls and so on, you can make the new sensors works with in 20 seconds after the power is on.When the nwe sensor works,the light will flash on time and with one "Di" sound for confirm.after 20 seconds,the alarm system  turns int o normal working.
    Test all sensors and repeat procedure for any  sensor,if it necessary.
    Maximum number of wireless sensors that can be coded by system is 16. But you can register countless wireless sensors by changing sensors' ID.
  • How to cancel the lost sensors in the alarm system
    When the wireless sensors are lost (like the remote contaoller,)  users need to clear this remote controller,making suer secure.Press the RESET key on the back of the alarm system and then plug in power, the signal light flashes once or the siren sounds"Di" for once,means the alarm system reset. After reset the alarm system,all setup comeback to the time when it came from factory, the password is 123456.
  • After sales service: 1 year warranty.
  • Login for Wholesale Discount Price, or back to Household burglar-alarm List.